KYN61-40.5 Armored Removable AC Metal-Enclosed Switchgear
+
  • KYN61-40.5 Armored Removable AC Metal-Enclosed Switchgear

KYN61-40.5 Armored Removable AC Metal-Enclosed Switchgear

Hengxuan Electric is committed to providing customers with research and development, production, sales, and installation (repair, testing) of complete electrical equipment and comprehensive supporting services.

Keywords: High and Low Voltage Complete Sets | Box-type Substation | Power Transformer

  • Description
  • Technical Specifications
    • Comprehensive mechanical safety interlock
    • Flexible solutions to meet diverse customer needs
    • Compact mechanism, stable performance
    • Passed the 40.5 kV full voltage internal arc 31.5 kA/1s test, meeting IAC AFLR level
    • Safe, reliable, with a full life cycle of up to 30 years
    • Metal enclosed, loss of continuity LSC2B level

    Product features:

    Modular center-mounted structure:

    Circuit breaker installed on a movable center trolley, easy operation and maintenance, strong interchangeability, supports quick replacement.

    Fully enclosed metal armor:

    Cabinet made of high-quality galvanized steel or aluminum-zinc plate, assembled in parts, high structural strength, protection level up to IP4X (internal compartments IP2X), excellent dust and moisture resistance.

    Combination of air insulation and composite insulation:

    Main busbar, branch busbar, and cable compartment use air insulation; key components (such as contacts) use silicone rubber or epoxy resin insulation to reduce maintenance requirements.

    Flexible scalability:

    Supports multi-cabinet splicing, easy busbar expansion, adaptable to different main wiring schemes (such as single busbar, single busbar sectionalizing, etc.).

    Safety performance:

    Interlock mechanism uses mechanical forced locking with high reliability. Equipped with comprehensive "five-prevention interlock" functions.

    Intelligent and monitoring functions (partially optional):

    1 Online monitoring system

    2 Contact temperature wireless monitoring (fiber optic or wireless sensor)

    3 Mechanical characteristic monitoring (opening and closing speed, travel)

    4 Partial discharge monitoring (UHF sensor)

    5 Environmental temperature and humidity monitoring and automatic heating and dehumidification

    Intelligent control device:

    Integrated temperature and humidity control, live display, open/close indication, voice prompts, remote communication (supports Modbus, IEC61850 protocols), realizing the "four remote" functions (remote measurement, remote control, remote signaling, remote adjustment).

    Pressure relief channel design:

    High-pressure gas generated by fault arcs can be directed out through the top pressure relief plate to prevent cabinet explosion.

  • Project Unit Data
    Rated Voltage kV 40.5 
    Rated Insulation Level 1 min Power Frequency Withstand Voltage kV 95 (General Value)/118 (Isolated Break)
    Lightning Impulse Withstand Voltage (Peak) kV 185 (General Value)/215 (Isolated Break)
    Rated Frequency Hz 50/60
    Main Bus Rated Current A 1250,1600,2000,2500,3150
    Branch Bus Rated Current A 1250,1600,2000,2500,3150*
    Rated Peak Withstand Current kA …63,80**
    Circuit Breaker Rated Short-Circuit Breaking Current kA …25,31.5
    Rated Short-Time Withstand Current (4 seconds) (RMS) kA …31.5**
    Operational Continuity Level  LSC2B
    Internal Arc Level IP IAC AFLR
    Protection Level   IP4X (Enclosure), IP2X (Cabinet Door Open and Compartments)
    Auxiliary Power Supply Voltage*** V DC110,220
      AC110,220
    Basic Cabinet Outline Dimensions mm H 2600
    mm W1400
    mm D 2865/3165

    Forced Air Cooling

    Current Transformer Needs Separate Consideration

    Other Auxiliary Power Supply Voltages Can Be Used According to Requirements

Application Industries