Vehicle-mounted mobile transformer
+
  • Vehicle-mounted mobile transformer

Vehicle-mounted mobile transformer

Hengxuan Electric is committed to providing customers with research and development, production, sales, and installation (repair, testing) of complete electrical equipment and comprehensive supporting services.

A mobile substation includes a mobile vehicle and the high and low voltage distribution devices, transformers, reactive power compensation, supporting secondary equipment, and communication equipment installed on the vehicle. It features flexible combinations, easy transportation, quick installation, and short construction periods. It also has advantages such as high integration, small size, low footprint, flexible site selection, convenient operation and use, low investment, and quick results.

Keywords: High and Low Voltage Complete Sets | Box-type Substation | Power Transformer

  • Description
  • Technical Specifications
  • A mobile substation includes a mobile vehicle and the high and low voltage distribution devices, transformers, reactive power compensation, supporting secondary equipment, and communication equipment installed on the vehicle. It features flexible combinations, easy transportation, quick installation, and short construction cycles. It also has advantages such as high integration, small size, low footprint, flexible site selection, convenient operation and use, low investment, and quick results.
    The bidding equipment provided by the bidder is a 110kV vehicle-mounted mobile substation, mainly composed of a 110kV substation vehicle, a 35kV substation vehicle, a 10kV distribution device vehicle, a 10kV reactive power compensation vehicle, cables, and their auxiliary equipment and materials.
    The 110kV substation vehicle includes: 110kV main transformer, neutral point complete set equipment, 110kV lightning arrester, 110kV voltage transformer, 110kV HGIS combined electrical apparatus, secondary equipment, cable transfer cabinet, prefabricated cabin, semi-trailer platform, and auxiliary equipment;
    The 35kV substation vehicle includes: 35kV main transformer, 35kV lightning arrester, 35kV voltage transformer, 35kV HGIS combined electrical apparatus, secondary equipment, cable transfer cabinet, prefabricated cabin, semi-trailer platform, and auxiliary equipment;
    The 10kV distribution device vehicle includes: 10kV switchgear, station transformer, secondary equipment, communication equipment, prefabricated cabin, semi-trailer platform, and auxiliary equipment;
    The 10kV reactive power compensation vehicle includes: 10kV reactive power compensation device, secondary equipment, prefabricated cabin, semi-trailer platform, and auxiliary equipment.
    Requirements for core equipment:
    The 110kV mobile substation main transformer has the special characteristics of oil-filled transportation and compact structure, and also requires high reliability. The main transformer module must use well-known brand vehicle-mounted special transformers; the protection, control, and communication equipment configured on the vehicle-mounted substation must all use products from manufacturers with outstanding performance records.

  • 110kV Substation Vehicle

    Name Specification Model Unit Quantity
    Main Transformer Section
    110kV Three-phase Dual-winding On-load Tap Changer Transformer Integrated Three-phase Dual-winding Oil-immersed Self-cooled On-load Tap Changer SZ-40000/110 Secondary Energy Efficiency Unit 1 
    Voltage Ratio: 110±8×1.25%/10.5kV
    Wiring Group: YNd11
    Cooling Method: ONAN
    3D Impact Recorder   Set 1 
    Neutral Point Complete Device Each set includes: Set 1 
    Maximum voltage 72.5kV, rated current 630A, creepage distance not less than 2248mm,
    Equipment brackets and matching installation iron parts
    Prefabricated Cabin (Including ventilation, temperature and humidity air conditioning, lighting, fire protection, and other equipment) Seat 2 
    Main Transformer Tap Terminal Box Stainless Steel Unit 1 
    10kV Tap Cabinet Indoor Gas-insulated High Voltage Switchgear, 12kV, 3150A, 31.5kA; Panel 1 
    10kV Insulated Pipe Busbar   3150A Meter Sufficient Quantity
    Lightning Arrester YH5WZ-17/45 Unit 3 
    110kV Distribution Device Section
    HGIS Combined Electrical Apparatus Three-phase Separate Box Arrangement Set 1 
    UN=110kV Maximum Operating Voltage 126kV Rated Current: 2000A
    Capacitive Voltage Transformer TYD110/ √3-0.02H Unit 3 
    110kV Zinc Oxide Lightning Arrester HY10W-102/266 Piece 3 
    Accessories Steel core aluminum stranded wire, equipment clamps, cable fixing brackets, etc. in the equipment room Set 1 
    Semi-trailer Vehicle and Accessories Width 3m, length determined according to the actual situation of the switchgear, equipped with fence, boarding handle, boarding ladder (with five-prevention lock hanging plate), folding work ladder,
    Horizontal calibrator (installed on two vertical sides outside the cabin), industrial air conditioner, industrial-grade heater, electric lifting lighting fixtures,
    Internal lighting fixtures and fire-fighting equipment inside the cabin, entrenching tool, crowbar, fire axe, spare tire, tire cover, sleepers, etc.
    Unit 1 
    Secondary Section
    110kV Main Transformer Protection Panel Includes: 2 sets of main transformer protection devices, 1 set of non-electric quantity protection device, 1 set each of high and low voltage operation boxes Panel 1 
    110kV Main Transformer Measurement and Control Panel Includes: 1 set of main transformer high voltage side measurement and control device, 1 set of main transformer low voltage side measurement and control device, 1 set of main transformer body measurement and control device, 2 sets of temperature indicators, 1 set of tap changer controller, 1 interval layer switch Panel 1 
    110kV Fault Recorder Panel Includes: 1 set of fault recording device, 1 printer Panel 1 

    35kV Distribution Vehicle

    Name Specification Model Unit Quantity
    Main Transformer Section
    35kV Three-phase Dual-winding On-load Tap Changer Transformer Integrated Three-phase Dual-winding Oil-immersed Self-cooled On-load Tap Changer SZ-20000/35 Secondary Energy Efficiency Unit 1 
    Voltage Ratio: 35±3×2.5%/10.5kV,
    Wiring Group: YNd11
    Cooling Method: ONAN
    3D Impact Recorder   Set 1 
    Prefabricated Cabin (Including ventilation, temperature and humidity air conditioning, lighting, fire protection, and other equipment) Seat 2 
    Main Transformer Tap Terminal Box Stainless Steel Unit 1 
    10kV Tap Cabinet Indoor Gas-insulated High Voltage Switchgear, 12kV, 2000A, 31.5kA Panel 1 
    10kV Insulated Pipe Busbar 2000A Meter Sufficient Quantity
    Lightning Arrester YH5WZ-17/45 Unit 3 
    35kV Distribution Device Section
    HGIS Combined Electrical Apparatus Three-phase Separate Box Arrangement Set 1 
      UN=35kV Maximum Operating Voltage 40.5kV Rated Current: 1250A   
    Capacitive Voltage Transformer TYD-35/ √3-0.02H Unit 3 
    35kV Zinc Oxide Lightning Arrester YH5WZ-51/134 Piece 3 
    Accessories Steel core aluminum stranded wire, equipment clamps, cable fixing brackets, etc. in the equipment room Set 1 
    Semi-trailer Vehicle and Accessories Width 3m, length determined according to the actual situation of the switchgear, equipped with fence, boarding handle, boarding ladder (with five-prevention lock hanging plate),
    Folding work ladder, horizontal calibrator (installed on two vertical sides outside the cabin), industrial air conditioner, industrial-grade heater,
    Electric lifting lighting fixtures, internal lighting fixtures and fire-fighting equipment inside the cabin, entrenching tool, crowbar, fire axe, spare tire, tire cover, sleepers, etc.
    Unit 1 
    Tertiary Section    
    35KV Main Transformer Protection Measurement and Control Panel Includes: 1 set of main transformer differential protection device, 1 set of high backup protection device, 1 set of low backup protection device, 1 set of non-electrical quantity protection device,
    1 set of main transformer measurement and control device, 2 temperature transmitters, 1 on-load tap changer controller. 1 bay layer switch.
    Panel 1 

    10kV Distribution Vehicle

    Name Specification Model Unit Quantity
    10kV Switchgear
    Main Transformer Incoming Cabinet Gas-insulated high-voltage switchgear, 12kV, 3150A, 31.5kA; Unit 1
    Feeder Switchgear Gas-insulated high-voltage switchgear, 12kV, 1250A, 31.5kA/4s; Unit 8 
    Busbar Equipment Cabinet Gas-insulated high-voltage switchgear, 12kV, 1250A, 31.5kA/4s; Unit 1 
    Capacitor Switchgear Gas-insulated high-voltage switchgear, 12KV, 1250A, 31.5kA/4s; Unit 1 
    Station Transformer Switchgear Gas-insulated high-voltage switchgear, 12kV, 1250A, 31.5kA/4s; Unit 1 
    Station Transformer 10kV, dry type, enclosed enclosure Set 1 
    Prefabricated Cabin (Including ventilation, temperature and humidity air conditioning, lighting, fire protection, and other equipment) Seat 2 
    Accessories Connection between equipment rooms, cables, fixed brackets, etc. Set 1 
    Semi-trailer Vehicle and Accessories Width 3m, length determined according to actual switchgear situation, equipped with fence, vehicle climbing handle, vehicle climbing ladder (with five-prevention lock hanging plate),
    Folding work ladder, horizontal calibrator (installed on two vertical sides outside the cabinet compartment), cabinet-type heptafluoropropane gas fire extinguishing device,
    Industrial air conditioner, industrial-grade heater, electric lifting lighting fixtures, internal cabinet lighting fixtures and fire-fighting equipment, entrenching tool,
    Crowbar fire axe, spare tire, tire protector, sleepers, etc.
    Unit 1
    Secondary Section
    Secondary parts dispersedly installed inside the switchgear
    10KV Line Protection Measurement and Control Device Set 1 
    10kV Line Protection Measurement and Control Device Set 8 
    10kV Capacitor Protection Measurement and Control Device Set 1 
    10kV Station Transformer Protection Measurement and Control Device Set 1 
    10kV Busbar Measurement and Control Device Set 1 
    Bay Layer Switch 24 ports, dual power supply, with fault contact Set 1 
    Intelligent Electric Energy Meter Three-phase three-wire intelligent electric energy meter, 0.5S class Piece 11 
    Secondary parts of centralized panel
    Host and Operator Workstation Includes: 1 set of monitoring host, 22" LCD monitor, speaker, keyboard, mouse, network A3 laser printer, etc. Set 1 
    Microcomputer Five-Prevention System Embedded, 110kV, 35kV, 10kV knife switch with five-prevention locks, electronic code lock, related cables, etc. Set 1 
    Public Measurement and Control and Time Synchronization Cabinet Includes: 1 public measurement and control device; 1 set of protocol conversion device, 1 set of time synchronization device (dual clock dual source, GPS+BD) Panel 1 
    Data Communication Gateway Cabinet Includes: 1 I-area data communication gateway (also graphic gateway), 1 I-area station control layer switch,
    1 II-area data communication gateway, 1 firewall, 1 network security monitoring device, 1 II-area switch, etc., 3 sets of probe programs
    Panel 1 
    Main Transformer Electric Energy Meter Panel Includes: 1 piece of 0.5S class three-phase four-wire intelligent electric energy meter, 2 pieces of 0.5S class three-phase three-wire intelligent electric energy meter, 4 junction boxes, 1 set of electric energy acquisition device Panel 1 
    Dispatch Data Network Panel Includes: 2 dispatch data network routers, 4 switches, 4 vertical encryption devices Panel 1 
    Video Surveillance System Includes: video host, hard disk, etc., 4 outdoor units, 6 indoor units, etc. Set 1 
    Fire Alarm System Includes: fire alarm host (wall-mounted), smoke and heat detectors, and cables Set 1 
    Temperature and Humidity System Set 1 
    Communication Part
    SDH/2.5G Optical Terminal Unit Regional Backbone Network Standard Type (including 2.5G, 622M, 155M optical interface boards, optical modules) Unit 1 
    Administrative IAD 16 ports Unit 1 
    Dispatch IAD 16 ports Unit  
    Access Router Unit 1 
    Optical Interface Board 2.5G Piece 1 
    Optical Module 2.5G Piece 1 
    Optical Interface Board 622M Piece 1 
    Optical Module 622M Piece 1 
    Optical Interface Board 155M Piece 1 
    Optical Module 155M Piece 1 
    Audio Distribution 30 circuits Set 1 
    Digital Distribution 16 systems Set 1 
    Optical Distribution 24 cores including storage cores Set 1 
    Grounding Wire BV-1×25 Meter 50 
    Pigtail 10 meters double-ended piece 20 
    Power cable ZC-W=2×10 Meter 100 
    Wiring cable HPVV-10×2×0.5 Meter 100 
    Telephone   unit 2 
    Network cable   Meter 50 
    2M cable   Meter 50 
    Non-metallic flame-retardant guided optical cable 12 cores Meter 300 
    Reel pay-off rack   unit 1 
    Patch cord 10 meters strip 10 
    Optical attenuation 5db unit 10 

    10kV reactive power compensation vehicle

    Name Specification Model Unit Quantity
    10kV shunt capacitor (total capacity 7800kvar)
    10kV shunt capacitor Indoor cabinet high-voltage shunt capacitor complete set Set 1 
    Capacity 1800kvar, rated voltage: 10KV;
    10kV shunt capacitor Indoor cabinet high-voltage shunt capacitor complete set Set 1 
    Capacity 2400kvar, rated voltage: 10kV;
    10kV shunt capacitor Indoor cabinet high-voltage shunt capacitor complete set Set 1 
    Capacity 3600kvar, rated voltage: 10kV;
    Prefabricated Cabin (Including ventilation, temperature and humidity air conditioning, lighting, fire protection, and other equipment) Set 2 
    Semi-trailer Vehicle and Accessories Width 3m, length determined according to the actual situation of the switch cabinet, equipped with fence, vehicle boarding handle, boarding ladder (with five-prevention lock hanging plate), etc. Unit 1 
    Secondary Section
    AC power screen Includes ATS dual power switch 1 set (DC control), 2 C-class lightning arresters, 2 electricity meters, monitoring modules, etc., 36 feeder switches;
    UPS single set configuration, capacity 5kVA, 9 feeder switches (with monitoring), 1 set of emergency lighting switching device, etc.
    Panel 1 
    DC charging screen Includes charging module (3+1)*10A, monitoring modules, etc. Panel 1 
    DC feeder screen 36 feeder switches, etc. Panel 1 
    Battery Includes battery inspection instrument, capacity 100AH DC220V 2V 104 units Panel 1 
    Communication power screen Communication 48V power module DC/DC, (2+1)*10A, 12 feeder switches (including monitoring modules), etc. Panel 1 

Application Industries

Message

If you have any needs, please feel free to contact us.

Submit Now
Business License