YBW11-(F·G) High Voltage/Low Voltage Prefabricated Substation (Huashi Type)
+
  • YBW11-(F·G) High Voltage/Low Voltage Prefabricated Substation (Huashi Type)

YBW11-(F·G) High Voltage/Low Voltage Prefabricated Substation (Huashi Type)

Hengxuan Electric is committed to providing customers with research and development, production, sales, and installation (repair, testing) of complete electrical equipment and comprehensive supporting services.

Keywords: High and Low Voltage Complete Sets | Box-type Substation | Power Transformer

  • Description
  • Technical Specifications
  • As a core equipment supplier in the wind power industry, Huabian focuses on developing efficient and reliable step-up and distribution solutions. Its products include wind power dedicated box-type substations, power transformers, and intelligent prefabricated substations, compatible with mainstream global wind turbine technology routes.

    Core Advantages:

    Efficient Heat Dissipation: Split-type heat dissipation design reduces temperature rise by 20-30%, ensuring stable operation in harsh environments from -40℃ to +55℃;

    Safe and Reliable: Supported by 12 patented technologies, five-prevention interlock protection system, with a failure rate only one-third of the industry average;

    Intelligent Operation and Maintenance: Real-time data monitoring + remote control, helping wind farms reduce costs and increase efficiency, cutting operation and maintenance costs by 30%.

    Product Features:

    Efficient Heat Dissipation and Temperature Control

    Exposed radiator design utilizes natural wind for cooling, reducing internal temperature rise of the box transformer by 20%-30%;

    Optimized box sealing (full door sealing strips + waterproof treatment for cable ports), resistant to extreme temperatures from -40℃ to +55℃.

    High Reliability and Safety

    The box uses 2.0mm cold-rolled steel plate, with anti-corrosion treatment + rib reinforcement, increasing structural strength by 40%;

    High-voltage side equipped with load switches/circuit breakers, combined with five-prevention interlock mechanism, reducing failure rate to one-third of the industry average.

    Intelligent Operation and Maintenance

    Built-in intelligent monitoring system supports remote viewing of real-time data (current, power, generation) and fault warnings;

    Optional GPRS/WIFI module enables unattended operation and maintenance, reducing labor costs by 30%.

    Environmental Protection and Energy Saving

    No-load loss <33kW (national standard requirement), energy efficiency level reaches first-class standard;

    Transformer oil uses 25# environmentally friendly type, reducing carbon emissions by 15%

  • Project Unit Parameter
    Rated Voltage on High Voltage Side kV 3, 6, 10, 20, 35
    Maximum Voltage on High Voltage Side 3.6, 7.2, 12, 24, 40.5
    Rated Voltage on Low Voltage Side V 315, 400, 550, 690, 800, 950
    Rated Current High Voltage Side A Depends on Transformer Capacity
    Low Voltage Side Depends on Transformer Capacity
    Rated Frequency Hz 50 

    Rated Peak Withstand Current

    1s Rated Short-time Withstand Current

    kA 16, 20, 22.5, 31.3, 40, 50, 63, 80, 100
    6.3, 8, 9, 12.5, 16, 20, 25, 31.5, 40
    Rated Insulation Level High Voltage Side Lightning Impulse Rated Voltage kV 40, 60, 75
    Withstand Voltage Maximum Voltage 46, 70, 85
    1min Power Frequency Rated Voltage 25, 30, 42
    Withstand Voltage Maximum Voltage 27, 34, 48
    Low Voltage Side Rated Voltage V 60≤UI≤300 300
    Lightning Impulse Withstand Voltage 2500              6000              8000              12000
    1min Power Frequency Withstand Voltage 2000              2500              3000              3500
    Transformer Rated Voltage on High Voltage Side kV 3               6                10              20               35
    Lightning Impulse Withstand Voltage 40             60             75             125             200/170
    1min Power Frequency Withstand Voltage 18/10             25/20             35/28             55/50             85/70
    Rated Noise Level Oil-cooled Transformer dB ≤54
    Dry-type Transformer ≤62
    Enclosure Protection Level Transformer Room  IP54
    High and Low Voltage Room IP54
    Box Transformer Enclosure Level K ≤30

Application Industries

Message

If you have any needs, please feel free to contact us.