SLVA Low Voltage Complete Switchgear (State Grid Standardization)
Hengxuan Electric is committed to providing customers with research and development, production, sales, and installation (repair, testing) of complete electrical equipment and comprehensive supporting services.
Keywords: High and Low Voltage Complete Sets | Box-type Substation | Power Transformer
- Description
- Technical Specifications
-
SLVA low-voltage switchgear is a mid-to-high-end switchgear designed according to the standardization requirements of the power distribution network, featuring "safe and reliable, sturdy and durable, standardized and unified, universally interchangeable, reasonably graded, and widely used." Its model name comes from the uppercase initials of Standardized Low-Voltage Assemblies, abbreviated as SLVA low-voltage switchgear.
According to the busbar current, SLVA low-voltage switchgear is divided into three specifications: 1250A, 2000A, and 2500A, unifying the primary, secondary, and civil interface technical requirements to facilitate construction and operation & maintenance. In addition, the product reserves intelligent management interfaces. The cabinet design uses high-strength profiles, with structural improvements and reinforcements; different functional areas are reliably isolated, and heat dissipation structures are added to the cabinet door and top to ensure the switchgear's protection level and temperature rise meet technical requirements.
This product complies with standards GB/T7251.1, GB/T7251.8, GB/7251.12, GB/T20641, GB/T15576, and others.
Product Features:
High Reliability Quality
The SLVA low-voltage complete system, relying on its design philosophy, rigorous experimental verification, and experience in the low-voltage electrical manufacturing field, ensures a high level of product reliability and safety.
Basic Guarantees Provided by SLVA Low-Voltage Complete Switchgear Equipment
Complies with national standards GB7251.1/12/Q/GDW12127-202, using standard components to ensure system operating status.
Excellent separation form fully ensures the safety of personnel and equipment.
Isolation between busbar and functional units.
Isolation between functional units.
Isolation between outgoing terminals and functional units.
Temperature Rise Test
Prevents normal operation from being affected by mis-tripping.
Prevents burns to maintenance personnel.
Short-time withstand strength.
Arc control inside the switchgear.
No electric shock risk when touching the enclosure.
Electrical clearance and creepage distance.
Arc control inside the switchgear.
No electric shock risk when touching the enclosure.
Protection Level.
Prevents personnel from touching dangerous parts and protects against external object impact.
Dielectric Performance.
Prevents premature aging of insulators.
Prevents electric shock risk when touching the enclosure.
Effectiveness of protective circuits.
Safety when personnel contact metal parts of the switchgear.
Mechanical Operation.
Verifies the lifespan of mechanical operating mechanisms.
Other Verification Tests.
Strength of materials and components.
Electric shock protection/protective circuit integrity.
Combination of switching devices and components.
Internal circuits and connections.
-
Item Unit Parameter Rated Operating Voltage V 400 Rated Insulation Voltage V 690(1000) Rated Impulse Withstand Voltage kV 8 Rated Operating Current Horizontal Main Busbar A ≤2500 Vertical Busbar A ≤1600 Operating Frequency Hz 50 Main Busbar Rated Short-Time Withstand Current kA 65 Main Busbar Rated Peak Withstand Current kA 143 Vertical Busbar Rated Short-Time Withstand Current kA 50 Vertical Busbar Rated Peak Withstand Current kA 105 Power Frequency Withstand Voltage (1min) V 2500 Dimensions (Width*Depth*Height) mm (700/1000)*800*2200 Protection Level IP4X